Model 1794-OE4XT identifies the FLEX XT four-channel analog output module. 1794-OE4XT is a Series B four-channel analog output module for extended-temperature installations, with selectable current or voltage ranges and documented safe-state values.
Item NO.:
1794-OE4XTBrand/ Manufacturer:
PLCDimensions:
45.7 x 94 x 53.3 mmWeight:
Not stated in cited manufacturer recordsCountry of Origin: :
Confirm on supplied product documentationDescription:
Four-channel analog output moduleMatch catalog number 1794-OE4XT, Series B, a listed terminal base, keyswitch position 4 and the existing four-channel output map. A neighboring input or mixed-I/O catalog number is not an interchangeable substitute.
Engineering note: Command and measure each channel at low, midpoint and high values, then test power-up and safe-state behavior before process release.
Installation planning
Confirm 1794-OE4XT enclosure protection, cabinet heat dissipation, mounting arrangement and documented environmental limits before installation.
Storage and handling
Keep 1794-OE4XT protected from moisture, contamination, impact and electrostatic discharge from receipt through installation.
Send the exact 1794-OE4XT model, required quantity, destination and installed hardware details. Request current nameplate photographs and confirm compatibility before ordering.
Use this module where four field outputs must deliver the documented 0 to 20 mA, 4 to 20 mA, 0 to 10 V DC or -10 to +10 V DC ranges in the approved distributed-I/O station.
Select by complete catalog number, output range, terminal-base type and Series B project record; appearance alone does not establish compatibility.
Lifecycle assessment: Confirm current availability and lifecycle status against the latest manufacturer notice for the exact article number.
Ordering check: Verify the full model, article number, hardware revision and supported project release before purchasing.
Complete these six checks against the current project documentation and the official exact-model record.
Retain the catalog and series label, terminal-base identity, output ranges, safe-state values and measured acceptance results in the asset record.
Handover must identify channel purpose, range, load, measured result, lifecycle decision and the approved replacement strategy.
It provides four single-ended, nonisolated analog output channels. Confirm the four-channel map before transferring field wiring. Record the result under 1794-OE4XT.
Each channel can be set for 0 to 20 mA or 4 to 20 mA. The selected range must agree with the receiving device and project scaling. Record the result under 1794-OE4XT.
The documented voltage selections are 0 to 10 V DC and -10 to +10 V DC. Verify polarity and common references before energization. Record the result under 1794-OE4XT.
The installation instructions list 1794-TB2, 1794-TB3, 1794-TB3S, 1794-TB3T, 1794-TB3TS and 1794-TBN. Record the result under 1794-OE4XT.
Use keyswitch position 4 for this catalog number. Do not force the module into a base keyed for a neighboring analog module. Record the result under 1794-OE4XT.
The nominal supply is 24 V DC and the documented operating range is 10.5 to 31.2 V DC, including the stated ripple allowance. Record the result under 1794-OE4XT.
For current service, keep the resistive load within 15 to 750 ohm at 24 V DC and include wiring resistance in the loop calculation. Record the result under 1794-OE4XT.
The output remains at 0 V or 0 mA until configuration is applied. Commission the range, data value and safe-state behavior under controlled conditions. Record the result under 1794-OE4XT.
The official instructions state that no calibration is required. Functional testing should still confirm commanded and measured output values. Record the result under 1794-OE4XT.
Record the exact catalog number, series, terminal base, range settings, safe-state values and project compatibility before selecting a functional replacement. Record the result under 1794-OE4XT.
Both PDFs are hosted on dcsmodule.com and prepared from the exact official manufacturer records for 1794-OE4XT cited on this page. They are independent Moore Automation references, not manufacturer-issued manuals.
Exact article identity, application context, procurement checks, replacement guidance and manufacturer-source trace.
OPEN SITE PDF → TECHNICAL DATAModel-specific specifications, compatibility boundaries, installation checks, commissioning guidance and official-source trace.
OPEN TECHNICAL DATA PDF →Ask for the exact 1794-OE4XT nameplate, hardware identification, revision, connector condition and packaging. Verify that the supplied unit carries the exact 1794-OE4XT identification.
| Specification | Official identification / verification note |
|---|---|
| Model | 1794-OE4XT |
| Article number | 1794-OE4XT |
| Lifecycle | End of life |
| Series | B |
| Analog outputs | 4, single-ended and nonisolated |
| Output resolution | 12 bits plus sign |
| Current ranges | 0 to 20 mA or 4 to 20 mA |
| Voltage ranges | 0 to 10 V DC or -10 to +10 V DC |
| Data format | Left-justified 16-bit two's complement |
| Conversion type | Pulse-width modulation |
| Step response | 24 ms to 63%, voltage or current terminal |
| Maximum voltage-output load current | 3 mA |
| Current-output resistive load | 15 to 750 ohm at 24 V DC |
| External supply | 24 V DC nominal; 10.5 to 31.2 V DC |
| External supply current | 165 mA at 24 V DC |
| Backplane current | 15 mA at 5 V DC |
| Maximum power dissipation | 4.5 W at 31.2 V DC |
| Maximum thermal dissipation | 13.6 BTU/hr at 31.2 V DC |
| Recommended terminal bases | 1794-TB2, TB3, TB3S, TB3T, TB3TS, or TBN |
| Keyswitch position | 4 |
| Approximate dimensions | 45.7 x 94 x 53.3 mm |
| Enclosure | Open-style |
| Operating temperature | -20 to +70 C |
| Storage temperature | -40 to +85 C |
| Relative humidity | 5 to 95%, noncondensing |
| Operating vibration | 5 g at 10 to 500 Hz |
| Shock | 30 g operating; 50 g nonoperating |
| Lifecycle | End of life; discontinuation announced for 2027-02-28 |
Technical-data note: Values shown here are limited to the exact model and explicitly documented assembly. Confirm field conditions and the applicable project release before installation.
More from this brand · Browse by category
Current PLC controller, interface and I/O references for adjacent exact-model checks.
Control and communication pages selected for installation and migration comparisons.
Measurement, sensing and field hardware for maintenance planning and signal verification.
Additional on-site industrial products supporting broader procurement research.
Send the full 1794-OE4XT model, required quantity and delivery country. Our team can check current availability and arrange nameplate photos, packaging images or live or recorded video verification where available.
Confirm the exact 1794-OE4XT model, available quantity, condition and estimated dispatch time.
Check the exact model, article number, hardware identification, revision and visible product condition.
Receive quotation, warranty terms, delivery options and international shipping support.
Send the full model, quantity and destination for quotation and availability checking.
Moore Automation kept the 1794-OE4XT request focused on article identity and the documented four single-ended nonisolated outputs with voltage or current range selection, which made our internal review straightforward.
Tiffany separated the 1794-OE4XT commercial quote from the required supported terminal base with keyswitch position 4 and shielded signal wiring checks and asked for clear label evidence before confirmation.