Definition

The AI880A 3BSE039293R1 is a High Integrity Analog Input Module within ABB's S800 I/O family, purpose-built for integration with the System 800xA distributed control platform. It provides 8 current input channels supporting both 0…20 mA and 4…20 mA single-ended unipolar inputs, with a fixed input resistance of 250 Ω and 12-bit resolution.


For deployment in both single and redundant configurations, the AI880A enables fault-tolerant analog signal acquisition without requiring external voter hardware. In redundant mode, two modules process identical field signals in parallel, delivering the high availability required for safety loops.

The AI880A incorporates advanced on-board diagnostics, including configurable over-range and under-range alarm limits compliant with NAMUR NE43, loop supervision, and a configurable alarm limit for field power outputs. It also supports HART pass-through communication, allowing asset management applications to access HART device parameters without additional hardware. Compatible termination units include TU834, TU844, TU845, and TU854.


Model Features

Module type: High Integrity Analog Input Module for S800 I/O
Channels: 8 current inputs, single-ended unipolar, one isolated group
Signal range: 0…20 mA / 4…20 mA, 250 Ω input resistance, 12-bit resolution
Physical form: Standard S800 I/O module, DIN-rail mount, yellow front panel with F/R/W/PRI status LEDs
Power: 24 V ModuleBus-powered; built-in supervised, current-limited transmitter supply per channel
Configuration: Single or redundant module operation
Communication: HART pass-through supported
Diagnostics: On-board diagnostics with NAMUR NE43 configurable over/under range limits
Safety rating: SIL 3 (IEC 61508), Category 4 (EN 954-1)
Termination units: TU834, TU844, TU845, TU854


Parameters Specifications

Detailed  Parameter

Part NumberAI880A 3BSE039293R1

Input impedance

250 Ω with shunt stick TY801

Input filter (rise time 0-90%)

190 ms (HW filter)

Update cycle time

10 ms

Rated insulation voltage

50 V

Dielectric test voltage

500 V a.c.

Power dissipation

2.4 W

Relative humidity

5 to 95 %, non-condensing

Temperature, Storage

-40 to +70 °C (-40 to +158 °F)

Protection class

IP20 according to IEC 60529


The difference between AI880A 3BSE039293R1 and AI890 3BSC690071R1

AI880A 3BSE039293R1

AI890 3BSC690071R1

Primary Focus

Functional Safety (High Integrity)

Intrinsic Safety (Hazardous Area)

Safety Certification

SIL3 (IEC 61508) & Category 4 (EN 954-1)

No SIL certification; features Intrinsic Safety interface

Application

Critical safety systems like ESD (Emergency Shutdown)

Direct connection to devices in Hazardous Areas (Zone 0)

HART Support

Yes, supports HART pass-through communication

Not standard (not specified in typical documentation)

Redundancy

Supports Single or Redundant configuration

Typically used in single configurations


Frequently Asked Questions

Does the AI880A support HART communication?
Yes. The AI880A supports HART pass-through communication, allowing asset management tools to access HART device data over the 4…20 mA loop.


What is the difference between single and redundant configuration for the AI880A?
In single configuration, one AI880A module handles all 8 channels. In redundant configuration, two AI880A modules operate in parallel with the same input signals, providing fault tolerance through hardware redundancy without external voter modules.


Can the AI880A power 2-wire field transmitters directly?
Yes. The module distributes transmitter supply to each channel. The supply is supervised and current-limited, enabling direct connection to 2-wire and 3-wire transmitters without additional external power supplies.


What does NAMUR NE43 compliance mean for the AI880A?
NAMUR NE43 defines standard signal levels for fault detection. The AI880A supports configurable over-range and under-range alarm limits, allowing the control system to distinguish between normal process values, out-of-range conditions, and wire-break/short-circuit faults.


Which termination units are required for the AI880A?
The AI880A is compatible with TU834, TU844, TU845, and TU854 module termination units. Selection depends on whether single or redundant configuration, shielding, and wiring practices are required.


Hot Selling Recommendations


Let's work together
Stuck in a critical breakdown situation? Moore Automation provides a myriad of services to clients across the globe. Contact us today to find out how our experienced team can help you minimise downtime.
Contact Us

Leave A Message

Leave A Message
If you are interested in our products and want to know more details,please leave a message here,we will reply you as soon as we can.

Home

Products

whatsapp