Model ATSS3S identifies the Yokogawa single analog-output pressure-clamp terminal block. An 8-point pressure-clamp terminal block for a single ASI533 analog output module in the documented built-in-barrier FIO configuration.
Item NO.:
ATSS3SBrand/ Manufacturer:
YokogawaDimensions:
60.5 x 32.6 x 114 mmWeight:
0.20 kgCountry of Origin: :
Confirm on supplied product documentationDescription:
single analog-output pressure-clamp terminal blockUse only with ASI533 in the documented single analog-output arrangement. Check loop load, polarity and intrinsically safe circuit documentation for the installed project before wiring.
Engineering note: Confirm ASI533 module identity and the single output arrangement before fitting the terminal block. Check every output-loop polarity, load and field-circuit designation against the project drawings. Allow cabinet clearance for the documented body dimensions and pressure-clamp wiring. Apply the required explosion-protection instructions when the output loop is intrinsically safe.
Installation planning
Confirm ATSS3S enclosure protection, cabinet heat dissipation, mounting arrangement and documented environmental limits before installation.
Storage and handling
Keep ATSS3S protected from moisture, contamination, impact and electrostatic discharge from receipt through installation.
Send the exact ATSS3S model, required quantity, destination and installed hardware details. Request current nameplate photographs and confirm compatibility before ordering.
An 8-point pressure-clamp terminal block for a single ASI533 analog output module in the documented built-in-barrier FIO configuration.
Use only with ASI533 in the documented single analog-output arrangement. Check loop load, polarity and intrinsically safe circuit documentation for the installed project before wiring.
Lifecycle assessment: Confirm current availability and lifecycle status against the latest manufacturer notice for the exact article number.
Ordering check: Verify the full model, article number, hardware revision and supported project release before purchasing.
Complete these six checks against the current project documentation and the official exact-model record.
Use only with ASI533 in the documented single analog-output arrangement. Check loop load, polarity and intrinsically safe circuit documentation for the installed project before wiring.
Confirm ASI533 module identity and the single output arrangement before fitting the terminal block Check every output-loop polarity, load and field-circuit designation against the project drawings Allow cabinet clearance for the documented body dimensions and pressure-clamp wiring Apply the required explosion-protection instructions when the output loop is intrinsically safe
No. Physical similarity is not proof of interchangeability; compare the exact model, function, terminals, connected hardware, option identity and current project documentation.
Review temperature range: -20 to 70 °C. Apply only limits stated for this exact model and arrangement.
Provide ATSS3S, quantity, destination, required date, installed companion hardware, cable or wiring details, current revision and clear nameplate photographs.
Keep ATSS3S in protective packaging, control moisture and contamination, use suitable electrostatic-discharge precautions and inspect terminals or connectors before use.
The technical basis is Yokogawa GS 33J60H40-01EN, Terminal Blocks for I/O Modules with Built-In Barrier and FIO. Use the current applicable revision for final engineering approval.
Record the ATSS3S identity, connected hardware, channel assignments, wiring checks and commissioning results in the maintenance record.
Check every output-loop polarity, load and field-circuit designation against the project drawings.
The complete ATSS3S identity distinguishes its documented function and connection path from similar products; shortened or assumed identities can lead to a wrong selection.
Use a clear nameplate image, the installed-system drawing, companion-hardware identification and the applicable Yokogawa table as the replacement evidence for ATSS3S.
Use only with ASI533 in the documented single analog-output arrangement. Check loop load, polarity and intrinsically safe circuit documentation for the installed project before wiring.
Both PDFs are hosted on dcsmodule.com and prepared from the exact official Yokogawa manufacturer records cited on this page. They are independent Moore Automation references, not manufacturer-issued manuals.
Exact article identity, application context, procurement checks, replacement guidance and manufacturer-source trace.
OPEN SITE PDF → TECHNICAL DATAModel-specific specifications, compatibility boundaries, installation checks, commissioning guidance and official-source trace.
OPEN TECHNICAL DATA PDF →Ask for the exact ATSS3S nameplate, hardware identification, revision, connector condition and packaging. Verify that the supplied unit carries the exact ATSS3S identification.
| Specification | Official identification / verification note |
|---|---|
| Model | ATSS3S |
| Application | Analog output, single |
| Connecting points | 8 |
| Connecting module | ASI533 |
| Terminal style | Pressure clamp |
| System role | Field termination for built-in-barrier FIO |
| Environmental class | ISA S71.04 class G3 |
| Temperature range | -20 to 70 °C |
| Dimensions | 60.5 x 32.6 x 114 mm |
| Approximate weight | 0.20 kg |
Technical-data note: Values shown here are limited to the exact model and explicitly documented assembly. Confirm field conditions and the applicable project release before installation.
More from this brand · Browse by category
Same-brand products are listed first, by other verified industrial-control references.
Verified industrial-control product references for related engineering and procurement work.
Verified industrial-control product references for related engineering and procurement work.
Verified industrial-control product references for related engineering and procurement work.
Send the full ATSS3S model, required quantity and delivery country. Our team can check current availability and arrange nameplate photos, packaging images or live or recorded video verification where available.
Confirm the exact ATSS3S model, available quantity, condition and estimated dispatch time.
Check the exact model, article number, hardware identification, revision and visible product condition.
Receive quotation, warranty terms, delivery options and international shipping support.
Send the full model, quantity and destination for quotation and availability checking.
Commercial follow-up was prompt, and the required technical evidence was easy for our engineers to prepare.
Tiffany kept the discussion centered on field wiring, cabinet conditions and the applicable official revision.