Model CC-PDOB01 identifies a Series C 24 VDC bussed digital output module with 32 source-output channels, diagnostics, electronic short-circuit protection and configurable safe-state behavior.
Item NO.:
CC-PDOB01Brand/ Manufacturer:
HoneywellDimensions:
Verify exact assembly dimensions before installationWeight:
Not stated in the cited Honeywell product recordsCountry of Origin: :
Confirm on supplied product documentationDescription:
32-channel source digital output moduleConfirm the exact product identity, connected hardware, field interface and current project release before installation.
Engineering note: Verify source-output polarity, the 15-30 VDC load supply, per-channel and per-module current limits, selected IOTA and configured safe-state behavior before energizing field loads.
Installation planning
Confirm CC-PDOB01 enclosure protection, cabinet airflow, mounting arrangement and documented temperature limits before installation.
Storage and handling
Keep CC-PDOB01 protected from moisture, contamination, impact and electrostatic discharge from receipt through installation.
Send the exact model, required quantity, destination and installed-hardware details. Request current nameplate photographs and confirm the required configuration before ordering.
A Series C 24 VDC bussed source-output module for field equipment, solenoid valves and interposing relays, with diagnostics, electronic short-circuit protection and configurable safe-state behavior.
Use the complete model, connected hardware and project definition when selecting a replacement. Physical similarity alone does not establish interchangeability.
Lifecycle assessment from the cited manufacturer evidence: Honeywell Experion Series C I/O Specification, EP03-490-520, Version 1.5 identifies the exact model or its documented hardware configuration, but the available source does not assign CC-PDOB01 a formal Active, Current, Mature, Discontinued or End-of-Life phase.
Ordering check: Confirm current stock, hardware revision, support status and exact replacement requirements with Tiffany before ordering.
These six checks apply to the exact installed assembly and should be completed against the current project documentation.
Record the IOTA field-power source, common arrangement and termination type on the approved output schedule.
For handover, retain the commanded state, short-circuit diagnostic recovery and final load-response evidence.
It is specified as a source-output module. Confirm field-device polarity and the common return before connection.
The module provides 32 output channels.
Honeywell specifies 0.5 A maximum per channel, subject to eight-channel group and overall module limits.
Electronic protection detects the short and removes power from that field connection. The cause must be repaired and the channel verified before return to service.
Yes. The bussed arrangement can use system or external 24 V power, selected through the IOTA wiring arrangement.
CC-TDOB01 is the listed non-redundant IOTA and CC-TDOB11 is the listed redundant IOTA.
Honeywell documents relay IOTAs CC-TDOR01 and CC-TDOR11, with CC-SDOR01 as the relay extension, for use with this IOM. The relay ratings must be checked separately.
FAILOPT can be set per channel to hold the last value or shed to a configured safe value. Validate these settings against the cause-and-effect design.
Confirm both module positions, IOTAs, redundancy state, field power, load current, safe-state configuration and project hardware definition.
No. CC-PDOB01 is a source-output model, while CC-PDOD51 is a sink open-drain model with different current and isolation ratings.
Both PDFs are hosted on dcsmodule.com and prepared from the exact official manufacturer records cited on this page. They are independent Moore Automation references, not manufacturer-issued manuals.
Exact article identity, application context, procurement checks, replacement guidance and manufacturer-source trace.
OPEN SITE PDF → TECHNICAL DATAModel-specific specifications, compatibility boundaries, installation checks, commissioning guidance and official-source trace.
OPEN TECHNICAL DATA PDF →Ask for the exact model and hardware revision, source-output identification, installed IOTA, field-power details, terminal condition and clear nameplate photographs. Verify that the supplied unit carries the exact CC-PDOB01 identification.
| Specification | Official identification / verification note |
|---|---|
| Model | CC-PDOB01 |
| Function | Field-isolated bussed 24 VDC digital output |
| Output channels | 32 |
| Output type | Source |
| Load voltage | 15-30 VDC maximum operating range |
| Maximum current | 0.5 A per channel; 6 A per module |
| Galvanic isolation | 1500 VAC RMS or +/-1500 VDC |
| Off-state leakage | 5.0 microamps maximum |
| Turn-on / turn-off | 10 ms maximum |
| Bussed IOTAs | CC-TDOB01 non-redundant; CC-TDOB11 redundant |
Technical-data note: Values shown here are limited to the exact model and explicitly documented assembly. Confirm field conditions and the applicable project release before installation.
More from this brand · Browse by category
Same-brand Honeywell modules and I/O assemblies
Control and I/O hardware for related engineering work
Termination, carrier and interface product references
Verified condition-monitoring product references
Send the full CC-PDOB01 model, required quantity and delivery country. Our team can check current availability and arrange nameplate photos, packaging images or live/recorded video verification where available.
Confirm the exact model, available quantity, condition and estimated dispatch time.
Check the exact model, hardware identification, revision and visible product condition.
Receive quotation, warranty terms, delivery options and international shipping support.
Send the full model, quantity and destination for quotation and availability checking.
The Moore Automation team presented the quotation clearly and helped keep the verification steps straightforward.
Tiffany coordinated the inquiry with clear answers and a concise checklist for compatibility confirmation.