Model CC-PDOD51 identifies a coated, field-isolated Series C 24 VDC bussed digital output module with 32 sink open-drain output channels.
Item NO.:
CC-PDOD51Brand/ Manufacturer:
HoneywellDimensions:
Verify exact assembly dimensions before installationWeight:
Not stated in the cited Honeywell product recordsCountry of Origin: :
Confirm on supplied product documentationDescription:
32-channel sink digital output moduleCC-PDOD51 operates as part of a Series C output assembly. Confirm the project hardware definition, selected IOTA, field polarity, load voltage and current before installation.
Engineering note: Verify sink open-drain polarity, 15–30 VDC load power, the 0.1 A per-channel maximum, IOTA selection and configured safe-state action before energizing field loads.
Installation planning
Confirm CC-PDOD51 enclosure protection, cabinet airflow, mounting arrangement and documented temperature limits before installation.
Storage and handling
Keep CC-PDOD51 protected from moisture, contamination, impact and electrostatic discharge from receipt through installation.
Send the exact model, required quantity, destination and installed IOTA details. Request current nameplate photographs and confirm the required redundancy arrangement before ordering.
A coated, field-isolated Series C 24 VDC bussed digital output module with sink open-drain outputs, diagnostics, electronic overcurrent protection and per-channel safe-state control.
Use the complete model, connected hardware and project definition when selecting a replacement. Physical similarity alone does not establish interchangeability.
Lifecycle assessment from the cited manufacturer evidence: Honeywell Experion Series C I/O Specification, EP03-490-520, Version 1.5 identifies the exact model or its documented hardware configuration, but the available source does not assign CC-PDOD51 a formal Active, Current, Mature, Discontinued or End-of-Life phase.
Ordering check: Confirm current stock, hardware revision, support status and exact replacement requirements with Tiffany before ordering.
These six checks apply to the exact installed assembly and should be completed against the current project documentation.
Record the measured load supply at the IOTA and retain the channel-current calculation with the cabinet drawing.
For handover, capture commanded-versus-observed output states and the approved FAILOPT result for every used channel.
It uses sink open-drain outputs. Field polarity and the common wiring must match this topology.
CC-PDOD51 provides 32 output channels.
Honeywell specifies 0.1 A maximum per channel.
Use CC-TDOD51 when the documented assembly requires the 9-inch non-redundant IOTA.
The 12-inch redundant configuration identifies CC-TDOD61 as its corresponding IOTA.
Yes. External field power can provide system-to-field isolation when wired according to the IOTA arrangement.
Honeywell lists latched, pulsed and pulse-width-modulated operation on a per-channel basis.
FAILOPT supports holding the last value or shedding to a configured safe value per channel.
Do not treat them as direct substitutes. Verify source-versus-sink topology, current rating, IOTA, field power and project hardware definition.
Confirm polarity, load current, commanded state, safe-state action, diagnostics and redundant switchover where applicable.
Both PDFs are hosted on dcsmodule.com and prepared from the exact official manufacturer records cited on this page. They are independent Moore Automation references, not manufacturer-issued manuals.
Exact article identity, application context, procurement checks, replacement guidance and manufacturer-source trace.
OPEN SITE PDF → TECHNICAL DATAModel-specific specifications, compatibility boundaries, installation checks, commissioning guidance and official-source trace.
OPEN TECHNICAL DATA PDF →Ask for the exact CC-PDOD51 nameplate, coated and field-isolated identification, installed IOTA, sink open-drain field polarity, terminal condition and packaging. Verify that the supplied unit carries the exact CC-PDOD51 identification.
| Specification | Official identification / verification note |
|---|---|
| Model | CC-PDOD51 |
| Function | Coated, field-isolated bussed 24 VDC digital output |
| Output channels | 32 |
| Output type | Sink, open drain |
| Load voltage | 15-30 VDC |
| Maximum load current | 0.1 A per channel |
| System-to-field isolation | 1000 VAC RMS with user-supplied field power |
| Off-state leakage | 100 microamps maximum |
| Turn-on / turn-off | 10 ms maximum |
| IOTAs | CC-TDOD51 non-redundant; CC-TDOD61 redundant |
Technical-data note: Values shown here are limited to the exact model and explicitly documented assembly. Confirm field conditions and the applicable project release before installation.
More from this brand · Browse by category
Same-brand Honeywell modules and I/O assemblies
Control and I/O hardware for related engineering work
Termination, carrier and interface product references
Verified condition-monitoring product references
Send the full CC-PDOD51 model, required quantity and delivery country. Our team can check current availability and arrange nameplate photos, packaging images or live/recorded video verification where available.
Confirm the exact model, available quantity, condition and estimated dispatch time.
Check the exact model, hardware identification, revision and visible product condition.
Receive quotation, warranty terms, delivery options and international shipping support.
Send the full model, quantity and destination for quotation and availability checking.
Moore Automation kept the quotation process clear, with the required order information presented in one place.