Model DO573 identifies the ABB 16-channel relay digital output module. A 16-channel S500-eCo relay output module for switching approved 24 V DC or 120/240 V AC loads up to 2 A per channel.
Item NO.:
DO573Brand/ Manufacturer:
ABBDimensions:
See exact-model technical dataWeight:
0.19 kgCountry of Origin: :
Confirm on supplied product documentationDescription:
16-channel relay digital output moduleMatch the complete DO573 and article 1SAP231300R0000, then verify the S500-eCo digital I/O hardware generation, local or distributed S500-eCo I/O bus role, connection method and approved configuration. Physical similarity is not proof of compatibility.
Engineering note: After fitting DO573, clear unrelated faults, confirm local or distributed S500-eCo I/O bus or channel status, exercise the affected path and archive the acceptance evidence.
Installation planning
Confirm DO573 enclosure protection, cabinet heat dissipation, mounting arrangement and documented environmental limits before installation.
Storage and handling
Keep DO573 protected from moisture, contamination, impact and electrostatic discharge from receipt through installation.
Send the exact DO573 model, required quantity, destination and installed hardware details. Request current nameplate photographs and confirm compatibility before ordering.
Use DO573 where the engineered system calls for sixteen normally open relay output channels through local or distributed S500-eCo I/O bus; retain the stated 24 V DC or 120/240 V AC loads up to 2 A per channel and the specified screw- or spring-connector set conditions in the installation design.
Select this exact article when 16 normally open relay outputs rated to 2 A is required. Confirm the surrounding assembly, software record and field interface instead of choosing by module appearance.
Lifecycle assessment: Confirm current availability and lifecycle status against the latest manufacturer notice for the exact article number.
Ordering check: Verify the full model, article number, hardware revision and supported project release before purchasing.
Complete these six checks against the current project documentation and the official exact-model record.
Keep AC and DC relay duties separated in the channel schedule.
Record contact operation under the approved load conditions before release.
Use the full DO573 label and 1SAP231300R0000 to identify this 16-channel relay digital output module.
Its selection basis is 16 normally open relay outputs rated to 2 A, so contact technology must remain unchanged.
DO573 supplies sixteen normally open relay output channels, allowing the specified AC or DC contact duties.
Tie the specified connector arrangement to the relay-contact schedule so AC and DC duties remain correctly separated.
Review each DO573 contact for 24 V DC or 120/240 V AC service and a load no greater than 2 A per channel.
Retain relay-contact allocation, AC/DC duty, wiring reference and output status.
No. The replacement must preserve normally open relay contacts, article 1SAP231300R0000 and the documented load duty.
Separate AC and DC relay conductors as designed; also verify ventilation, orientation and ESD protection.
Witness every used relay contact changing state under the approved circuit arrangement.
Describe AC/DC contact duties, article 1SAP231300R0000, channel use, quantity and destination.
Both PDFs are hosted on dcsmodule.com and prepared from the exact official ABB manufacturer records cited on this page. They are independent Moore Automation references, not manufacturer-issued manuals.
Exact article identity, application context, procurement checks, replacement guidance and manufacturer-source trace.
OPEN SITE PDF → TECHNICAL DATAModel-specific specifications, compatibility boundaries, installation checks, commissioning guidance and official-source trace.
OPEN TECHNICAL DATA PDF →Ask for the exact DO573 nameplate, hardware identification, revision, connector condition and packaging. Verify that the supplied unit carries the exact DO573 identification.
| Specification | Official identification / verification note |
|---|---|
| Model | DO573 |
| Order code | 1SAP231300R0000 |
| Module family | S500-eCo digital output |
| Digital outputs | 16 |
| Contact form | Normally open relay |
| Supported load voltage | 24 V DC or 120/240 V AC |
| Per-channel current | 2 A maximum |
| Input channels | None |
| Connector options | One screw or one spring connector set |
| Catalog weight | 0.19 kg |
| Load review | Check resistive, inductive and inrush duty |
| Suppression | Apply load-appropriate external suppression where needed |
| Replacement boundary | Contact arrangement and voltage class must match |
| Commissioning focus | Isolation, contact action and load response |
Technical-data note: Values shown here are limited to the exact model and explicitly documented assembly. Confirm field conditions and the applicable project release before installation.
More from this brand · Browse by category
Current ABB controller, interface and I/O references for adjacent exact-model checks.
Control and communication pages selected for installation and migration comparisons.
Measurement, sensing and field hardware for maintenance planning and signal verification.
Additional on-site industrial products supporting broader procurement research.
Send the full DO573 model, required quantity and delivery country. Our team can check current availability and arrange nameplate photos, packaging images or live or recorded video verification where available.
Confirm the exact DO573 model, available quantity, condition and estimated dispatch time.
Check the exact model, article number, hardware identification, revision and visible product condition.
Receive quotation, warranty terms, delivery options and international shipping support.
Send the full model, quantity and destination for quotation and availability checking.
Moore Automation separated the DO573 commercial scope from the 16 normally open relay outputs rated to 2 a checks, so our review stayed concise.
Tiffany kept the DO573 inquiry tied to the article number and requested the correct installation evidence before confirming the match.