Brand/ Manufacturer:
General ElectricDimensions:
3.4 x 14.5 x 1.4 cmWeight:
0.6 kgCountry of Origin: :
United StatesDescription:
PLC Machine Control
Mfr. Part Number: |
IC693PTM101 |
Manufacturer: |
General Electric |
|
|
Description: |
IC693PTM101 POWER TRANSDUCER MODULE |
Contact Details: |
E-mail:plcsale@mooreplc.com Skype:dddemi33 Whatsapp/Wechat:+86 18030235313 Manager: Tiffany
|
|
|
Status: |
Hope we can do more business soon ! There will become your honest cooperation partners!
IC693PTM101 is a Power Transducer Module, which includes the Processing module, interfacing board and 1-meter interface cable, manufactured by GE Fanuc Automation. It facilitates the interface of the PTM with input transformers.
The interfacing is achieved via the 1-meter cable connection between module and interface board. One of the PTM’s component is a Series 90-30 PLC module; the PLC can use the data gathered by the PTM for data reporting, fault monitoring, general control, or demand charge reduction/load shedding applications.
With a mature life-cycle status, IC693PTM101 operates with an input voltage ranging from 10Volts to 120Volts AC. The range for the input current is from 0Amps to 7.5Amps RMS. The frequency is within a range of 35Hz up to 70Hz, with zero outputs.
The IC693PTM101 processes data at impressive rates. It generates data calculations at a rate of of 20ms when operating at 50Hz, and 16.67ms at the rate of 60Hz. The module’s latency for data rates are 15ms when operating at 50Hz and 16.67ms when operating at 60Hz. Data is also analysed for energy and power based on the reactive and active power noted for each phase and the sum in Watts and Volt-Amperes-Reactive (VAR) in addition to the total reactive and active energy consumed in Watt-Seconds.
Volt-Amperes-Reactive-Seconds (revised every second), re-adjustable manually, the sum of power factor, aggregate reactive and real power consumed (15 mins window revised every second) are also analysed by the IC693PTM101 module.
The IC693PTM101 diagnostics and status support features make troubleshooting manageable and hasten the entire process. These include the indicators such as Module Heartbeat (indicating the health module), voltage present in a utility phase, valid phase polarity reading, valid Voltage measurements, and valid Current measurements. The power which is being used internally by the IC693PTM101 is 400mA at 5 Volts DC.
ProcessingModule Power Requirements |
|
Backplane Power Consumption Total Power Dissipation: |
5V @ 400mA max. (from 90-30 backplane) 4W max. |
Isolation from Backplane |
1500V |
Measurement Specifications |
|
MONITOR Mode |
|
1 x 3-phase voltage (PT): |
|
Impedance: |
>200k ohms |
Range: |
10 -- 150 VAC RMS (120VAC nominal) |
Frequency: |
35-70 Hz |
1 x 3-phase current (CT) and neutral |
|
current |
|
Impedance: |
<50mï— |
Range: |
0 – 7.5A RMS (5A nominal) |
Frequency: |
35-70 Hz |
SYNCHRO Mode: |
|
1 x 3-phase voltage + 1 x 1-phase |
|
voltage (generator + grid) |
|
Impedance: |
>200k ohms |
Range: |
10 -- 150 VAC RMS (120VAC nominal) |
Frequency: |
35-70 Hz |
Phase: +/- |
180O |
1 x 3-phase current + 1 neutral |
|
current |
|
Impedance: |
<50mï— |
Range: |
0 – 7.5A RMS (5A nominal) |
Frequency: |
35-70 Hz |