Part number VE4001S2T1B1 is listed by Emerson as 8-Channel 24 V DC Isolated Discrete Input with Standard I/O Termination Block.
Item NO.:
VE4001S2T1B1Brand/ Manufacturer:
EmersonDimensions:
8-Channel 24 V DC Isolated Discrete Input with Standard I/O Termination BlockWeight:
Not stated in the current official product data sheetCountry of Origin: :
Not stated in the current official product data sheetDescription:
Match the isolated-input function, standard terminal block keying, field voltage and channel wiring before installation.8-Channel 24 V DC Isolated Discrete Input with Standard I/O Termination Block. Match the isolated-input function, standard terminal block keying, field voltage and channel wiring before installation.
Installation planning
Confirm VE4001S2T1B1 protection, enclosure airflow, mounting arrangement and operating temperature before installation.
Storage and handling
Protect VE4001S2T1B1 from impact, contamination, moisture and electrostatic discharge before installation.
Send the full part number, required quantity and destination. Request current photos, approval markings and connector details before ordering.
Part number VE4001S2T1B1 is listed by Emerson as 8-Channel 24 V DC Isolated Discrete Input with Standard I/O Termination Block.
VE4001S2T1B1 belongs to the Emerson DeltaV M-series Traditional I/O hardware family. Its exact ordering suffix defines the electrical function and termination arrangement; selection must be based on the full model, not on physical appearance alone.
Purchasing check: Lifecycle status is separate from exact product identification. Confirm current orderability, supported hardware revision, condition and lead time with Emerson or the sales team.
Important: Approve replacements only after the full model, hardware revision, carrier or termination arrangement, field power and site requirements have been checked.
Use the following checks to confirm that the exact VE4001S2T1B1 configuration fits the installed DeltaV system.
Match the isolated-input function, standard terminal block keying, field voltage and channel wiring before installation.
Technical basis: Emerson DeltaV M-series Traditional I/O Product Data Sheet, March 2026
It is the eight-channel 24 V DC isolated discrete-input configuration; confirm each device can meet the greater-than-10 V on threshold and less-than-5 V off threshold.
Yes. Emerson specifies optical isolation from the system and between channels, factory tested to 1500 V DC.
No field-circuit power is provided by this card configuration; engineer the external 24 V DC field supply and protection separately.
The official specification states 5 mA at 24 V for the isolated input.
No automatic substitution should be made. The isolated-input electrical behavior, wiring and terminal-block key differ and must be reviewed.
Use 75 mA typical and 100 mA maximum at 12 V DC nominal for the engineering power-budget check.
The I/O interface plugs into an M-series I/O carrier, and the function-key system must match the correct terminal block before insertion.
Check IP20 enclosure protection, -40 to 70 °C operating temperature, non-condensing humidity and ISA G3 airborne-contaminant requirements.
Verify polarity, channel assignment, field-supply commoning, terminal torque, keying, shield and grounding practice, and that no channel exceeds the documented input limits.
Ask for the complete model and revision, clear nameplate and connector photographs, terminal-block type, quantity, condition and compatibility confirmation.
Only Emerson official documents are linked below. Use the current data sheet for engineering and ordering; use the archived edition only to compare legacy installed hardware.
March 2026 · Current ordering information, supported I/O functions, terminal-block options, environmental limits and engineering data.
OPEN EMERSON PDF → OFFICIAL PDFFebruary 2016 · Legacy ordering tables and historical installation information for comparison with installed hardware.
OPEN EMERSON PDF →Ask for current product photos, the complete nameplate, connectors, packaging and a live or recorded inspection video where available. Verify that the supplied unit carries the exact VE4001S2T1B1 code and matches the required 8-Channel 24 V DC Isolated Discrete Input.
| Ordering configuration | Discrete input card, 8 channels, 24 V DC, isolated; standard I/O termination block |
|---|---|
| Channels | 8 |
| Channel isolation | Optically isolated from system and each other; factory tested to 1500 V DC |
| On detection level | Greater than 10 V DC |
| Off detection level | Less than 5 V DC |
| Input current | 5 mA at 24 V |
| LocalBus current | 75 mA typical; 100 mA maximum at 12 V DC nominal |
| Field circuit power | None |
| Operating temperature | -40 to 70 °C (-40 to 158 °F) |
| Storage temperature | -40 to 85 °C (-40 to 185 °F) |
| Relative humidity | 5 to 95%, non-condensing |
| Protection rating | IP20 |
| Corrosion protection | ISA-S71.04-1985 Class G3; conformal coating |
| Dimensions | 10.7 × 4.1 × 10.5 cm (H × W × D) |
Tiffany-supported product directory · 24 unique links
Six distinct industrial automation products with Tiffany contact support.
Six distinct industrial automation products with Tiffany contact support.
Six distinct industrial automation products with Tiffany contact support.
Six distinct industrial automation products with Tiffany contact support.
Send the full VE4001S2T1B1 code, required quantity and delivery country. Our team can check current availability and arrange nameplate photos, packaging images or live/recorded video verification where available.
Confirm the full model, available quantity, condition and estimated dispatch time.
Check the exact model, hardware revision, terminal or carrier arrangement and visible product condition.
Receive quotation, warranty terms, delivery options and international shipping support.
Send the full model, quantity and destination for quotation and availability checking.
Moore Automation organized the VE4001S2T1B1 request around the exact input module and provided a clear path through quotation review.
Tiffany handled the VE4001S2T1B1 technical questions carefully and summarized the field-wiring checks needed before ordering.