Part number VE4005S2B4 is listed by Emerson as 16-Channel 4-20 mA HART AO Plus with 16-Channel Terminal Block.
Item NO.:
VE4005S2B4Brand/ Manufacturer:
EmersonDimensions:
16-Channel 4-20 mA HART AO Plus with 16-Channel Terminal BlockWeight:
Not stated in the current official product data sheetCountry of Origin: :
Not stated in the current official product data sheetDescription:
Check the Series 2 Plus terminal block, 16-loop power budget, HART scan demand and simplex or redundant configuration before commissioning.16-Channel 4-20 mA HART AO Plus with 16-Channel Terminal Block. Check the Series 2 Plus terminal block, 16-loop power budget, HART scan demand and simplex or redundant configuration before commissioning.
Installation planning
Confirm VE4005S2B4 protection, enclosure airflow, mounting arrangement and operating temperature before installation.
Storage and handling
Protect VE4005S2B4 from impact, contamination, moisture and electrostatic discharge before installation.
Send the full part number, required quantity and destination. Request current photos, approval markings and connector details before ordering.
Part number VE4005S2B4 is listed by Emerson as 16-Channel 4-20 mA HART AO Plus with 16-Channel Terminal Block.
VE4005S2B4 belongs to the Emerson DeltaV M-series Traditional I/O hardware family. Its exact ordering suffix defines the electrical function and termination arrangement; selection must be based on the full model, not on physical appearance alone.
Purchasing check: Lifecycle status is separate from exact product identification. Confirm current orderability, supported hardware revision, condition and lead time with Emerson or the sales team.
Important: Approve replacements only after the full model, hardware revision, carrier or termination arrangement, field power and site requirements have been checked.
Use the following checks to confirm that the exact VE4005S2B4 configuration fits the installed DeltaV system.
Check the Series 2 Plus terminal block, 16-loop power budget, HART scan demand and simplex or redundant configuration before commissioning.
Technical basis: Emerson DeltaV M-series Traditional I/O Product Data Sheet, March 2026
This exact model is the 16-channel 4-20 mA HART Series 2 Plus configuration with the matching 16-channel AO terminal block.
The official Series 2 Plus AO specification gives a full range of 1-23 mA for 4-20 mA devices.
The Series 2 Plus AO card supports simplex and redundant engineering, but the terminal block and project configuration must match the intended mode.
Use 85 mA typical and 150 mA maximum LocalBus current and up to 400 mA field-circuit power at 24 V DC ±10%.
For the card pair, use the redundant LocalBus figure of 110 mA typical and 260 mA maximum per documented configuration, and verify the redundant terminal block.
It provides HART pass-through for asset-management use plus HART variable and status reporting for control functions.
Emerson gives a typical 600-800 ms per enabled channel; include enabled-channel count in diagnostics and update-time planning.
No. The 16-channel Series 2 Plus card requires the correct 16-channel AO terminal-block configuration and matching keying.
Verify terminal keying, loop polarity, 24 V field-power capacity, grounding, HART impedance and the channel schedule before commissioning.
Match the complete model, Series 2 Plus revision, simplex/redundant mode, terminal block, firmware support and engineering database assignment.
Only Emerson official documents are linked below. Use the current data sheet for engineering and ordering; use the archived edition only to compare legacy installed hardware.
March 2026 · Current ordering information, supported I/O functions, terminal-block options, environmental limits and engineering data.
OPEN EMERSON PDF → OFFICIAL PDFFebruary 2016 · Legacy ordering tables and historical installation information for comparison with installed hardware.
OPEN EMERSON PDF →Ask for current product photos, the complete nameplate, connectors, packaging and a live or recorded inspection video where available. Verify that the supplied unit carries the exact VE4005S2B4 code and matches the required 16-Channel HART Analog Output Plus Interface.
| Ordering configuration | 16-channel 4-20 mA HART Plus card with 16-channel AO terminal block |
|---|---|
| Channels | 16 |
| Full signal range | 1 to 23 mA |
| Accuracy over temperature | 0.25% of span |
| Resolution | 14-bit A/D converter |
| Isolation | Each channel optically isolated from system; factory tested to 1000 V DC |
| LocalBus current, simplex | 85 mA typical; 150 mA maximum |
| LocalBus current, redundant | 110 mA typical; 260 mA maximum |
| Field circuit power | 400 mA maximum at 24 V DC ±10% |
| HART scan time | 600-800 ms typical per enabled channel |
| Operating temperature | -40 to 70 °C (-40 to 158 °F) |
| Storage temperature | -40 to 85 °C (-40 to 185 °F) |
| Relative humidity | 5 to 95%, non-condensing |
| Protection rating | IP20 |
| Corrosion protection | ISA-S71.04-1985 Class G3; conformal coating |
| Dimensions | 10.7 × 4.1 × 10.5 cm (H × W × D) |
Tiffany-supported product directory · 24 unique links
Six distinct industrial automation products with Tiffany contact support.
Six distinct industrial automation products with Tiffany contact support.
Six distinct industrial automation products with Tiffany contact support.
Six distinct industrial automation products with Tiffany contact support.
Send the full VE4005S2B4 code, required quantity and delivery country. Our team can check current availability and arrange nameplate photos, packaging images or live/recorded video verification where available.
Confirm the full model, available quantity, condition and estimated dispatch time.
Check the exact model, hardware revision, terminal or carrier arrangement and visible product condition.
Receive quotation, warranty terms, delivery options and international shipping support.
Send the full model, quantity and destination for quotation and availability checking.
The Moore Automation team made the VE4005S2B4 purchasing review straightforward by presenting the requested model and documentation clearly.
Tiffany responded promptly to the VE4005S2B4 questions and organized the HART interface compatibility checks for review.