Tricon EcoStruxure™ Triconex Safety Systems
October 25, 2021
The Tricon™ platform is the gold standard in safety instrumented systems. Overview Based on industry-leading Triconex™ triple modular redundant (TMR) technology, Tricon has logged more than one billion hours with no failure on demand. The Tricon system is certified by TÜV Rheinland for use in safety applications up to Safety Integrity Level 3 (SIL 3). It is also marine-certified and nuclear 1E-certified. Features Communications and integration Online module replacement to ensure continuous operation and plant availability Integration with EcoStruxure Foxboro DCS and all major distributed control systems (DCSs) Comprehensive family of I/O modules Up to 254 nodes of peer-to-peer communications Achilles Level 1 cybersecurity certification Maintenance Built-in diagnostics and redundancy management — transparent to user Easy diagnostics for status and fault analysis Online modifications and changes, online module replacement and hot spare slot for continuous production without halting operations Full set of software tools for every stage of the safety life cycle (TriStation™ suite) What is the Tricon? The Tricon is a state-of-the art controller that provides fault tolerance by means of Triple-Modular Redundant (TMR) architecture. TMR integrates three isolated, parallel control systems and extensive diagnostics in one control system. The system uses two-out-ofthree voting to provide high-integrity, error-free, uninterrupted process operation with no single point of failure. A Tricon system is composed of a main chassis and up to 14 expansion or remote expansion (RXM) chassis. The maximum system size is 15 chassis supporting a total of 118 I/O modules and communication modules that interface with OPC clients, Modbus devices, other Tricons, and external host applications on Ethernet (802.3) networks, as well as Foxboro and Honeywell distributed control systems (DCS). Get lastest best price by Email plcinfo@mooreplc.com Whatsapp : + 8618020776786 Description Model No Chassis Assemblies Main Chassis, High Density Configuration, includes the Tricon printed manuals 8110 Expansion Chassis, High Density Configuration 8111 Remote Expansion Chassis, High Density Configuration 8112 Power Modules 120 VAC/VDC – 175-Watt Power Module 8310 24 VDC – 175-Watt Power Module 8311 230 VAC – 175-Watt Power Module 8312 Main Processor Modules 3008 Main Processor, 16 megabytes DRAM 3008 Communication Hardware and Software Tricon Communication Module (TCM), Ethernet (802.3) and serial (RS-232/RS-485) ports 4351A, 4352A, 4353, 4354 Enhanced Intelligent Communication Module (EICM), serial (RS-232/RS-422/RS-485) ports 4119, 4119A Safety Manager Module (SMM), Honeywell UCN Interface 4409 Network Communication Module (NCM), Ethernet (802.3) ports 4329, 4329G Digital Input Modules 115 VAC/VDC Opto-Isolated, Non-Commoned TMR 3501E/3501T 48 VAC/VDC Commoned in Groups of 8, Self-Test TMR 3502E 24 VAC/VDC Commoned in Groups of 8, Self-Test TMR 3503E 24/48 VDC High Density, DC Coupled TMR...
More